Processor Olympus Evis CV-180

The Olympus 180 Video proceesor provides an image display on image for any combination of endoscopy, fluoroscopy, ultrasound, laparoscopic and images of the position detection unit of the endoscope. The Scope IDTM function for easy administration of endoscopy and expansion of next-generation system. Auto Iris has eliminates the need to change between peak and average required in the conventional manual adjustment.

Formulario de Contacto Productos
Primer y segundo nombre
Apellidos completos
PARA MAS INFORMACIÓN CONTÁCTENOS AL:

Clic Aquí-Enviar mensaje a WhatsApp

+57 304 355 13 63

+57 4 322 36 03

+1 707 294 8221

Description

  • Equipped with HDTV imaging capability of high resolution to ensure the best possible image quality for endoscopy and laparoscopy.
  • Compatible with EVIS EVIS 100/130/40 and EXERATM 160 Series models as well as bronchoscopes and surgical endoscopes
  • Narrow Band ImagingTM (NBI) to improve visibility of fine and mucosal tissues in the gastrointestinal tract.
  • There are two types of improvement of the structure: the original type A for observing larger mucosal tissues with high contrast and the new B type for the observation of smaller tissues such as capillaries.
  • Electronic magnification magnifies images moving or still with the touch of a button by 1.2x or 1.5x without loss of quality.

Processor specifications Olympus Evis CV-180

Dimensions

  • Tamaño: 370 (W) x 91 (H) x 462 (D) mm
  • Weight: 10.5kg

Power

  • Voltage (voltage fluctuation): 100 ~ 120V AC 220 ~ 240 (within +/- 1%)
  • Frequency (frequency fluctuation): 50/60 Hz (within +/- 1%)
  • Power consumption: 150 VA
  • Fusible: 5A, 250V
  • Fuse size: 5, 20mm

Iris

  • Auto iris modes can be selected using the switch “iris mode” on the front panel. Pico: to use when observing by focusing on a small bright area. Auto: to use notes when focusing on the center of the image.

Media

  • XD-Picture Card (512/256/128/64/32/16 MB) specified by Olympus. MAPC-10 can be used as PC card adapter.

Recording Format

  • TIFF: uncompressed, SHQ: approx. 1/3 HQ: approx. 1/5 SQ: approx. 1/10.

Number of images Recording

  • 16MB, NTSC / PAL, TIFF: approx. 17/14 images, SHQ: approx. 80/60 images, HQ: approx. 200/150 images, SQ: approx. ** / ** images.

HDTV signal output

  • You can select the output RGB or YPbPr

SDTV signal output

  • VBS composite (NTSC / PAL), Y / C and RGB; Simultaneous output possible.

Adjusting the white balance

  • Automatic white balance adjustment is possible using the white balance switch on the front panel.

Standard output color chart

  • You can display a color bar graph by pressing the “Shift” + “F7” keys “arrow” on the keyboard.

Automatic Gain Control (AGC)

  • Image is electrically amplified when light is inadequate because the distal end of the endoscope is too far from the object.

Reviews

There are no reviews yet.

Be the first to review “Processor Olympus Evis CV-180”

Your email address will not be published. Required fields are marked *